Pre-assembled through fixing anchor insulation materials.
Substrates
Concrete
Hollow floor beams
Solid block
Solid brick
Stone
Applications
Fixing of rigid insulation onto solid materials. Internal and external insulation boards NB: The anchor must be protected from UV rays by a suitable screen such as rendering or panelling.
SPECIFICATIONS
The expansion portion of the anchor is set by hammering in an integral expansion nail. Material Expansion nail: Glass reinforced polamide 6 (Except part 057600 - Polypropylene). Anchor Body:Polypropylene Thermal conductivity:0.12 W/m - °C Temperature Range in use:-30°C to +80°C
FEATURES & BENEFITS
Rough cast head provides a key for render
Quick and easy to install through the insulation Ø 50 for rigid insulation material
Very good performance in hollow materials
Rigid, watertight glass fibre nail
Plastic anchor reduces cold bridging compared with metal fixings
Deep profile and expansion legs ensure excellent pullout resistance even in hollow block and lightweight materials
Sealing ring prevents passage of moisture through anchor body
Serrated shank gives added pullout resistance
TRADES & APPLICATIONS
INSTALLATION GUIDE
Drill a hole through the insulation material according to the total length of anchor plus 20mm.
Insert the anchor until the head contacts the insulating material. The anchoring depth in the base material must be at least 30mm.
Insert the expansion nail in the anchor. Then expand with a hammer until the nail is flush.